Gathering Laser

Solution

Ampoule micropores


1. Material and Requirements Analysis

  • Ampoule MaterialGenerally borosilicate glass (high temperature resistant, chemically stable), with a thickness of approximately 0.5-1.5 mm.
  • Aperture RequirementsMicrometer level (e.g., 50-200 μm), requiring no cracks and smooth edges to ensure drug sterility and sealing.

2. Laser Selection

  • Recommended Laser Type
  • Ultrafast laser (femtosecond/picosecond)Small heat-affected zone, suitable for brittle glass, reducing cracks.
  • CO₂ laser (10.6 μm)High glass absorption rate, but thermal stress needs to be controlled.
  • Wavelength SelectionUltraviolet or mid-infrared band (such as 355 nm or 9.4 μm) to improve absorption.

3. Key Process Parameters

  • Pulse EnergyAdjust according to thickness to avoid excessive heat damage (e.g., femtosecond laser: 1-10 μJ).
  • Repetition Rate1-100 kHz, combined with scanning speed (such as 100-1000 mm/s) for efficient processing.
  • Focusing SpotUse a high NA lens (such as NA≥0.5), spot diameter ≈ wavelength × NA⁻¹ (such as 1 μm level).
  • DefocusFine-tune the focal position to control the aperture and penetration depth.